Can a electrical panel be near a sink?

There is no specific code requirement for the minimum distance from a plumbing fixture to an electric panel, but nothing—including a sink—is allowed to be installed in a working space 2′-6” wide by 3′-0” deep by 6′-6” high in front of an electric panel.

How far away does an electrical panel need to be from a sink?

Every bathroom must have at least one electrical outlet. It must be a GFCI, and it must be within 3 feet of the edge of the sink. Either behind or beside the sink is acceptable — across from the sink on an opposite wall is not. If the bathroom has two sinks, each must have an electrical receptacle within 3 feet.

How far does a panel have to be from water?

An electrical panel is required to have a clear area in front of it that is 30-inches wide by 36-inches deep and 78-inches high for service, per National Electrical Code [NEC 110.26 (A)(1)].

Can an electrical panel be located in a kitchen?

You cannot put it over anything. You cannot put it next to anything. There must a clear space in front of the panel for an electrician to stand. The space must be kept clear for at least 3 feet in front of the panel, and for 30 inches left to right in front of the panel.

THIS IS INTERESTING:  Do solar panels refract light?

Where can you not put an electrical panel?

A panel cannot be located: 1) Where exposed to physical damage. 2) In the vicinity of easily ignitable material. Clothes closets are specifically noted as an area with easily ignitable material (hanging clothes).

Where should I place my electrical panel?

Best Locations for Electrical Panel

  1. Garages – attached garages are the best location for an electrical panel, as they provide enough space to comply with the clear workspace requirements, but are also quite hidden.
  2. Basements – the basement is another preferable location for your electrical panel.

Is it legal to cover an electrical panel?

Is It Legal To Cover An Electrical Panel? You are allowed to cover your electrical panel but it must be easy to open, can not interfere with the opening of the steel door of the panel and you have to make sure you have full access to all of the breakers.

Can you put a refrigerator in front of an electrical panel?

I have a nook / large closet that would be the perfect place to put my fridge. … We are in the process of remodeling, so we are constantly going to the panel to turn off the electricity, so my fridge is not in there now. But once we are done, I don’t really see a need for the easy access to the electrical panel.

Can I build a closet around my electrical panel?

ANSWER: According to Section 240-24(d) of the National Electrical Code (NEC), which says “Overcurrent devices shall not be located in the vicinity of easily ignitable material, such as in clothes closets,” you are not permitted to do this.

THIS IS INTERESTING:  What type of energy is the input energy of a vehicle?

Can an electrical panel be in a bathroom closet?

As long as the working space in the closet is enough, it’s fine. That closet is not in the bathroom.